Análisis de la fiabilidad de un sistema de telecontrol frente a fallos accidentales o provocados (Analysis of the Reliability of a Remote Control System in Response to Accidental or Consequential Failures)

9 Pages Posted: 31 Jan 2018

See all articles by F. Javier Martínez-Solano

F. Javier Martínez-Solano

Technical University of Valencia (Valencia Tech)

Pedro L. Iglesias-Rey

Polytechnic University of Valencia

Brayan J. Torres-Chazatar

Polytechnic University of Valencia - Department of Hydraulic Engineering and Environment

Daniel Mora-Melia

University of Talca

Date Written: November 30, 2017

Abstract

Spanish Abstract: La comprensión, el análisis y el mejoramiento de los procesos relacionados con los abastecimientos urbanos se han convertido en uno de los principales objetivos de la mayoría de países a nivel mundial. El empleo de la telemedida y el telecontrol de las redes facilitan la operación de las mismas, dando respuestas eficaces a cambios en las circunstancias de funcionamiento.

Hoy en día y sobre todo a raíz del resurgimiento de determinados grupos terroristas de carácter global ha crecido la preocupación por la seguridad frente a ataques. Una de las muchas medidas tomadas a tal efecto fue la aprobación de diversas normativas en las que se establecen medidas para la protección de las infraestructuras críticas. Todas estas normativas coinciden en incluir las infraestructuras hidráulicas (tanto de agua potable como de aguas residuales) en el catálogo de infraestructuras críticas.

Los sistemas de telecontrol tienen como riesgo añadido la posibilidad de sufrir no solo fallos físicos, sino también ataques cibernéticos. Por todo ello, cualquier estrategia que permita establecer un sistema de control de la calidad de las señales recibidas supone una importante aportación al problema. Este trabajo pretende establecer una estrategia de control de las señales recibidas por el sistema de telecontrol de forma que ante un fallo fortuito o intencionado, éste sea detectado y corregido a tiempo.

El trabajo se aplicará a una red de estudio ampliamente conocida como es el caso de la red de C-Town. Los resultados demuestran que es posible establecer mecanismos de control de los datos que permitan detectar anomalías con cierta celeridad y con un porcentaje de falsos negativos (anomalías no detectadas) muy bajo.

English Abstract: Understanding, analyzing and improving processes related to urban supplies has become one of the main objectives of most countries worldwide. One of the main interests of these is the good use of the resource that is increasingly scarce, as well as protection of infrastructure and good control of subscribers' consumption. The use of telemetry and remote control of the networks facilitates the operation of the same, giving effective responses to changes in operating circumstances.

Today, and especially as a result of the resurgence of certain terrorist groups of a global character, the concern for security against attacks has grown. One of the many measures taken to this end was the adoption of various regulations that establish measures for the protection of critical infrastructures. All these regulations agree to include hydraulic infrastructures (both drinking water and waste water) in the catalog of critical infrastructure.

Remote control systems have the added risk of suffering not only physical failures but also cyberattacks. Therefore, any strategy that allows establishing a system of control of the quality of the received signals supposes an important contribution to the problem. This work tries to establish a strategy of control of the signals received by the remote control system so that in the event of an accidental or intentional failure, this were detected and corrected in time.

The protocol presented in this work is applied to a benchmark network also known as C-Town. Results prove the possibility of establishing control mechanism to data which allow the detection of faults with velocity and a low rate of false negatives (undetected faults).

Note: Downloadable document is in Spanish.

Keywords: water supply systems, remote sensing, reliability

Suggested Citation

Martínez-Solano, F. Javier and Iglesias-Rey, Pedro L. and Torres-Chazatar, Brayan J. and Mora-Melia, Daniel, Análisis de la fiabilidad de un sistema de telecontrol frente a fallos accidentales o provocados (Analysis of the Reliability of a Remote Control System in Response to Accidental or Consequential Failures) (November 30, 2017). Ibero-American Seminar on Water and Drainage Networks (SEREA 2017), Available at SSRN: https://ssrn.com/abstract=3108124 or http://dx.doi.org/10.2139/ssrn.3108124

F. Javier Martínez-Solano (Contact Author)

Technical University of Valencia (Valencia Tech) ( email )

Camino de Vera, s/n
Valencia, Valencia 46022
Spain

HOME PAGE: http://www.upv.es/ficha-personal/jmsolano

Pedro L. Iglesias-Rey

Polytechnic University of Valencia ( email )

Camino de Vera, s/n
Valencia, Valencia 46022
Spain

Brayan J. Torres-Chazatar

Polytechnic University of Valencia - Department of Hydraulic Engineering and Environment

Camino de Vera
Building 4E
Valencia, 46022
Spain

Daniel Mora-Melia

University of Talca ( email )

2 Norte 685
Talca, 3460000
Chile

Do you have negative results from your research you’d like to share?

Paper statistics

Downloads
43
Abstract Views
398
PlumX Metrics